Specifications:
Standardapplied: IEC651 type 2, ANSI S1.4 type 2
Frequencyrange: 31.5Hz~8KHz
Measuringlevel range: 30~130dB
Frequencyweighting: A/C
Microphone:1/2 inch electret condenser microphone
Calibration: Electrical calibration with theinternal oscillator (1kHz sine wave)
Digitaldisplay : 4 digits
Resolution:0.1dB
DisplayUp data: 0.5 s
Timeweighting : FAST(125mS), SLOW(1 sec.)
Accuracy:±1.5dB (under reference conditions)
Maximumhold: Hold readings the Maximum Value
Autopower off: Meter automatically shuts down after approx. 10 minutes
Powersupply: One 9V battery, 006P or IEC 6F22 or NEDA 1604.
Powerlife: About 50hrs
Operationtemperature: 0 to 40oC(32 to 104oF)
Operationhumidity: 10 to 90%RH
Storagetemperature: -10 to 60oC( 14 to 140 oF)
Storagehumidity : 10 to 75%RH
Dimensions:215(L)X80(W)X45(H)mm
230g(including battery)