1

Product Detail

ET310B

Place of origin : China
Brand name : KSET
Model number : ET310B
Dimesion : 86 *186 * 32mm
Weight : 325g
Warranty : 12 Months
Detail
Display128 x 128 pixel graphic LCDViewing Area71.7 mm x 71.7mm
Back LightWhite LED, 3 levels of brightnessInput Impedance10MΩ
PowerInner Polymer Li-Ion Battery or AC adapterAuto Power Off5~60minutes adjustable with disable feature
Indication of low powerYesCharging timeAbout 3hrs
Battery life12~16hrs approx. (vary with different models)Memory100 records (both DMM data and DSO waveform)*
Operational conditions0°C to +50°C (+32°F to +122°F); < 75%RHStorage conditions-10°C to +60°C (-14°F to 140°F)
Dimensions86 mm ´ 186 mm ´ 32mmWeight325g ( without the holster and other accessories)



* The ET310A has only 50 records.
Auto power off in 5~60min or continuous on
Inner Polymer Li-Ion Battery with AC adapter
Isolated USB/RS232 interface with PC
Digital Storage Oscilloscope


Simulation bandwidthD DC ~ 10MHz(50mV/div ~ 10V/div)Maximum real-time sampling rate50Msps
The vertical resolution8 bitsNonlinearity+-1 bit
Channel number1CouplingDC/AC/GND
Input impedanceabout 10MΩindexingVertical +- 4.8, horizontal 12.8
Vertical sensitivity range50mV/div ~ 200V/divWhen range0.20µs/div ~ 20s/div
Vertical amplitude precision+-(5%+ 0.1div)When accuracy+-(0.01% + 0.1div)
Automatic zero referenceIn DC/dB measurementScanning modeAuto/normal/single
Trigger level+- 12 div (At each step, 0.1div)Trigger slopeRising along/down along
Trigger position adjustment+- 6 div (At each step, 0.1div)Automatic SettingsWhen the vertical amplitude and automatic Settings
The cursor measurement functiondV, dt, 1/dt (Frequency)Automatic measurement functionVp-p, Vavg, RMS, dBm
Automatic measurement accuracy+-(5%+ 0.1div)Record length12.8div



* 10MHz refers to simulate bandwidth to 3db voltage when the attenuation of bandwidth, when the input signal interference,
change with ADP08 and special high frequency shield.
* 1-2-5 for vertical attenuation switch range
Digital Multimeter


FunctionRangeResolutionAccuracy
DC Voltage400.0mV0.1mV+-(0.75%rdg + 10dgt)
4.000V1mV
40.00V10mV
400.0V100mV
1000V1V+- (1.5%rdg + 10dgt)
AC Voltage (True RMS)400.0mV0.1mV
50Hz~1kHz: +-(1.0%rdg + 10dgt);
1kHz~10kHz: +-(2.0%rdg + 10dgt);
10kHz~50kHz: +-(3.0%rdg + 10dgt);
(above 50kHz not specified)
4.000V1mV
40.00V10mV
400.0V100mV
750V1V50Hz~1kHz : +- (1.5%rdg + 10dgt)
DC Current40.00/400.0mA10/100µA+-(1.2%rdg + 10dgt)
4.000/20.00A1/10mA
AC Current (True RMS)40.00/400.0mA10/100µA+-(1.5%rdg + 10dgt)
50Hz~1kHz (above 1kHz not specified)
4.000/20.00A1/10mA
Resistance400.0W0.1 Ω+-(1.0%rdg + 5dgt)
4.000K1 Ω
40.00K10 Ω
400.0K100 Ω
4.000MW1K
40.00MW10K+- (3.0%rdg + 5dgt)
Capacitance51.20nF1pF+- (2%rdg + 10dgt)
512.0nF10pF+- (1%rdg + 3dgt)
5.120μF100pF+- (1%rdg + 3dgt)
51.20μF1nF+- (1.5%rdg + 3dgt)
100.0μF10nFMay need 30 sec.
Frequency Counter5.12Hz ~ 5.12MHz0.1Hz ~ 1kHz+- (1.0%rdg + 5dgt), (The signal amplitude ³ 3Vp-p, AC V or 20mA RMS, AC A)
Duty Cycle0.1~99.9%
DiodeOpen circuit voltage 1.5 V, maximum current about 1.5mA
ContinuitySound when lower than 30Ω
Auto rangeFor every function
Over rangeIndicates “O. L” (Over load)
Measurement rate2.5 times/sec.
Dynamic Data WindowKeep the data in the window live In hold mode.
dB (-80 ~ +80dB) reference2, 3, 8, 16, 50, 75, 93, 110, 125, 135, 150, 300, 600, 900, 1000, 1200 Ω
FusePhi5×20,0.5A/250V



 
 
 Work Time
Mon to Fri :8:30-17:30
Sat to Sun :9:00-17:00
 Contact Details
Tel:+86-596-2522787
E-mail:Export@kasuntest.com