1

Product Detail

ET4401

Place of origin : China
Brand name : East Tester
Model number : ET4401
Dimesion : 265*105*305mm
Weight : 2.3Kg
Warranty : 12 Months
Detail

Measurement frequency up to 100kHz

Test level 100 ~ 2000mV

Support the measurement of DC resistance and electrolytic capacitor

Internal bias voltage output (1mV-1500mV)

Automatic identification of component measurement

3.5-inch TFT display, 5 and a half bits display

USB, RS232 communication interface, Handle sorting

Data recording function (maximum and minimum values, average value)

Support SCPI communication protocol

Provide system settings, which can configure language, buzzer, screen brightness, etc according to the needs of users.

Basic accuracy 0.2%

Manual and automatic range

Be equipped with open circuit and short circuit correction

Comparator has sorting and alarm function

Provide a variety of test ports



Model

ET4401

ET4402

ET4410

ET4501

ET4502

ET4510

Digits

Main parameter: 5 digits; secondary parameter: 5 digits

Measurement Parameter

Main parameter: L/C/R/Z; secondary parameter: X/D/Q/θ/ESR

Measurement Range(L)

0.01μH - 9999H

Measurement Range(C)

0.01pF - 99999μF

Measurement Range(R)

0.0001Ω - 99.99MΩ

Basic Accuracy

0.2%

Test Frequency (Hz)

100~10kHz   10 point

100~20kHz   12point

100~100kHz   16 point

10~10kHz   1Hz Stepping

10~20kHz   1Hz Stepping

10~100kHz   1Hz Stepping

Measurement Display Speed

2 times/second (slow), 4 times/second (medium speed), 8 times/sec (fast)

Internal Bias

0-1500mV adjustable, 1mV stepping

Test Level

100mV,300mV,600mV,1000mV,1500mV,2000mV

0.1V~2V adjusted   ,1mV   Stepping   

Correction Function

Open circuit correction, short circuit correction

Screening function

The screening limit can be set from -50% to + 50% with fixed points of 1%, 5%, 10% and 20%

Selection of comparator

Five gear sorting, third gear qualified, one gear failed, one ancillary gear

Communication Interface

Standard configuration: USB, RS232 (or 485), Handle interface; Optional: GPIB, USB Host

Others

Support DCR, electrolytic capacitor measurement mode, adjustable backlight brightness,   optional in English and Chinese


Power connection

(1) Power supply voltage range: 220V AC ± 10%, or 110V AC ± 10%.

(2) Power supply frequency range: 45-65Hz.

(3) Phase line L, zero line N, and ground line E of power input shall be the same as those of the power plug of this instrument.

(4) The instrument has been carefully designed to reduce the clutter interference caused by the input at the AC power supply terminal. However, it shall be used in a low noise environment. If such is not the case, please install the power supply filter.

WARNING: In order to prevent leakage from causing damage to the instrument or person, the user must ensure that the ground line of the power supply is reliably connected to the earth.

(5) Power consumption: less than 20W.

1.1 General Technical Specifications

Power supply voltage: 220V AC ± 10%, or 110V AC ± 10%, 45-65Hz

Working environment: 0 ~ 40 ℃, relative humidity <80%.

Storage environment: -10 ~ 50 ℃, relative humidity <80%.

Dimensions: 265mm * 105mm * 305mm (width * height* depth).

Mass: 2.3kg.


Standard Accessories:

Four-terminal-pair Kelvin test cable (35A51).

Three-core power cord (30A51).

One User Manual.


Optional accessories:

RS232 serial cable / USB data cable.

Handle cable.

Four-terminal-pair Kelvin test fixture (including short block)

SMD component test fixture (including short block


 
 
 Work Time
Mon to Fri :8:30-17:30
Sat to Sun :9:00-17:00
 Contact Details
Tel:+86-596-2522787
E-mail:Export@kasuntest.com